Usability & Human Factors Testing

Evaluation of your usability engineering process and file to IEC 60601-1-6 and IEC 62366-1, with an ASCA summary test report for your FDA 510(k).

  • IEC 60601-1-6
  • IEC 62366-1
  • FDA human factors guidance
Preparing a 510(k)? Consult with a medical device test expert.

Why Sigma

Usability evidence FDA reviewers recognize

We check that your usability engineering process is complete, traceable and tied to your risk management, so the evidence holds up in review.

  • FDA ASCA-accredited for IEC 60601-1-6: your report comes with an ASCA summary test report for the 510(k).
  • Clause by clause against IEC 62366-1: use specification, user interface, hazard-related use scenarios and evaluation records.
  • Linked to risk management: we check that use errors trace to your ISO 14971 hazards and risk controls.
  • One program with IEC 60601-1: usability is evaluated together with electrical safety and the other collateral standards.
Usability engineer observing a participant using a medical device touchscreen during an evaluation session

What we evaluate

Every part of your usability engineering file

Reviewed for completeness, traceability and consistency with your risk management file. See how we measure →

Use specificationIntended users, use environments, operating principle and the conditions of use
Safety-related UI characteristicsUser interface elements that can lead to use errors with harm
Known use problemsUse problems from similar devices, complaints and field data
Hazard-related use scenariosScenarios selected for evaluation and how they were prioritized
User interface specificationDesign requirements for the user interface and their traceability
Formative evaluationsRecords of early evaluations and how findings changed the design
Summative evaluationProtocol, participants, tasks, acceptance criteria and results
Accompanying documentsInstructions for use and training, evaluated as part of the user interface

Standards we test to

Standards and accreditation status

Each result is reported under the accreditation that covers it.

StandardScopeAccreditation
IEC 60601-1-6Collateral standard: usability of medical electrical equipmentASCA · A2LA
IEC 62366-1Application of usability engineering to medical devices, as required by IEC 60601-1-6Via IEC 60601-1-6
FDA guidance (February 3, 2016)Applying human factors and usability engineering to medical devicesFollowed
ISO 14971Risk management: use-related hazards and risk controlsReferenced

Don’t see your standard? Contact us; we will tell you whether we can test to it and how it would be reported.

When you need it

From first submission to post-market

Support across the product life cycle, for new devices and for changes to cleared ones.

01New 510(k) submissionFull IEC 60601-1-6 evaluation of your usability engineering file.
02User interface changesNew screens, software, alarms or controls: we evaluate what the change affects.
03Before the summative studyReview of hazard-related use scenarios, critical tasks and the protocol before you recruit.
04Home use devicesLay users and home environments, evaluated together with IEC 60601-1-11.
05Use-related complaintsPost-market use problems fed back into the file and the risk analysis.

Your challenges, our solutions

What manufacturers ask us most

“Our usability file was written after the design was finished.”

We show you what is missing so the file traces use scenarios to risk controls and design decisions.

“Which tasks belong in the summative test?”

We review your hazard-related use scenarios and critical tasks before you recruit participants.

“FDA asked for human factors data.”

We help you scope the human factors evidence and present it the way the FDA guidance expects.

Your test report

A report ready to file

Clause-by-clause verdicts with the evidence from your usability engineering file.

  • Clause-by-clause verdicts for IEC 60601-1-6 and IEC 62366-1
  • Review of the use specification and user interface specification
  • Traceability from use errors to hazards and risk controls
  • Assessment of formative and summative evaluation records
  • Findings and gaps, with the clause and evidence
  • ASCA summary test report (within ASCA scope)

Additional services

Complementary human factors support

Support for every stage of your human factors program.

Formative usability sessionsEarly sessions with representative users to find use problems before design freeze.
Summative protocol reviewReview of your human factors validation protocol against the FDA guidance.

Accreditation

Accredited where it matters

TL-114FDA ASCA accredited testing laboratory. IEC 60601-1-6 is within our ASCA scope.See our FDA listing →
4896.01A2LA accredited to ISO/IEC 17025:2017 for medical electrical equipment test methods.Scope of accreditation →
24 hQuote response with scope, price and timeline for your device.Request a quote →

FAQ

Frequently asked questions

Is the report accepted by FDA as an ASCA report?

IEC 60601-1-6 is within our ASCA scope, so you receive an ASCA summary test report for your 510(k).

Is IEC 60601-1-6 the same as FDA human factors validation?

They are related but not the same. IEC 60601-1-6 checks your usability engineering process through IEC 62366-1; FDA also expects human factors validation results as described in its guidance. We help you line up both so one body of evidence supports the submission.

What do I need to send?

Your usability engineering file, the risk management file, the instructions for use and training materials, and access to the device or a representative prototype. We send a checklist with the quote.

How fast can I get a quote?

Within 24 hours. Tell us the device, its users and use environments, and we reply with scope, price and timeline.

Request a usability quote

Tell us about your device and the standards you need. You’ll have a quote within 24 hours.

(305) 239-4441 info@sigmascientific.us 490 Sawgrass Corporate Parkway, Suite 130, Sunrise, FL 33325

Request a Quote