Endoscope Safety Testing

Basic safety and essential performance testing of endoscopic equipment to IEC 60601-2-18, from endoscopes to camera heads and light sources, with an ASCA summary test report for your FDA 510(k).

  • IEC 60601-2-18
  • IEC 60601-1
  • ANSI/AAMI ES60601-1
Preparing a 510(k)? Consult with a medical device test expert.

Why Sigma

Endoscope safety data FDA reviewers recognize

We test the endoscope together with the equipment it is used with, against the particular standard and the general standard, in one program and one report.

  • FDA ASCA-accredited for IEC 60601-2-18: your report comes with an ASCA summary test report for the 510(k).
  • The whole endoscopic system: endoscopes, camera heads, camera control units and light sources, tested in the combinations you market.
  • Rigid and flexible endoscopes: leakage current, insulation and temperature of every part that contacts the patient.
  • One program with IEC 60601-1: particular and general requirements tested together for the same system.
Test engineer connecting a flexible endoscope system to an electrical safety analyzer

What we test

Every clause your submission needs

Tested for each endoscope model and each combination of equipment you declare. See how we measure →

Patient leakage currentType BF and CF applied parts, in normal condition and single fault condition
Combined leakageThe endoscope used together with endotherapy devices, such as high frequency surgical equipment
Dielectric strengthInsulation of the insertion portion and the parts that contact the patient
Distal end temperatureSurface temperature of applied parts and of the light emitting surface
Light sources and guidesTemperatures and protection at the light guide connection and output
Ingress of fluidsProtection against fluids from use, cleaning, disinfection and sterilization
Mechanical hazardsSharp edges, insertion tube and the mechanical strength of accessible parts
Marking and documentsCompatible combinations of endoscopes, camera heads, light sources and accessories

Standards we test to

Standards and accreditation status

Each result is reported under the accreditation that covers it.

StandardScopeAccreditation
IEC 60601-2-18Particular requirements for the basic safety and essential performance of endoscopic equipmentASCA · A2LA
IEC 60601-1General requirements for basic safety and essential performanceASCA · A2LA
ANSI/AAMI ES60601-1US national version of IEC 60601-1, recognized by FDAASCA · A2LA

Don’t see your standard? Contact us; we will tell you whether we can test to it and how it would be reported.

When you need it

From first submission to post-market

Support across the product life cycle, for new devices and for changes to cleared ones.

01New 510(k) submissionFull IEC 60601-2-18 evaluation of a new endoscope or endoscopic system.
02New system combinationsA new camera head, light source or processor: we test the combinations you add.
03Design or material changesA new insertion tube, distal end or seal: we retest what the change affects.
04Use with endotherapy devicesLeakage and insulation with high frequency surgical and other endotherapy devices.
05Reprocessing changesNew cleaning or sterilization methods checked against fluid ingress and insulation.

Your challenges, our solutions

What manufacturers ask us most

“Which combinations of camera and light source do we need to test?”

We map your system configurations to the clauses that apply and tell you which combinations to send.

“Our distal end runs hot with the new light source.”

We measure the surface temperatures at the distal end and the light guide, and report them against the limits.

“The endoscope will be used with HF surgical devices.”

We test leakage current and insulation for that use, so the combination is covered in the report.

Your test report

A report ready to file

Clause-by-clause results with the measurements behind every verdict, per system configuration.

  • Clause-by-clause verdicts for IEC 60601-2-18 and IEC 60601-1
  • Patient and combined leakage current measurements
  • Dielectric strength of the insertion portion
  • Surface temperatures at the distal end and light guide
  • Tested combinations of endoscope, camera and light source
  • ASCA summary test report (within ASCA scope)

Additional tests

Complementary optical performance tests

Optical performance to the ISO 8600 series is within our A2LA ISO/IEC 17025 scope.

Optical performanceField of view, direction of view and resolution, following the ISO 8600 series. See the service →
Image qualityDistortion, uniformity, noise and color reproduction of the imaging system.

Accreditation

Accredited where it matters

TL-114FDA ASCA accredited testing laboratory. IEC 60601-2-18 is within our ASCA scope.See our FDA listing →
4896.01A2LA accredited to ISO/IEC 17025:2017 for medical electrical equipment test methods.Scope of accreditation →
24 hQuote response with scope, price and timeline for your system.Request a quote →

FAQ

Frequently asked questions

Is the report accepted by FDA as an ASCA report?

IEC 60601-2-18 and IEC 60601-1 are within our ASCA scope, so you receive an ASCA summary test report for your 510(k).

Do I need to send the whole system?

Yes. We test the endoscope with the camera head, camera control unit and light source it is marketed with. We confirm the configurations and number of units in the quote.

Do you test rigid and flexible endoscopes?

Yes. Both are covered by IEC 60601-2-18, and we adapt the setup to the insertion portion and the applied parts of each design.

How fast can I get a quote?

Within 24 hours. Tell us the endoscopes, the equipment they are used with and the standards you need, and we reply with scope, price and timeline.

Request an endoscope safety quote